 INTRODUCTION

Clamped electromagnetic flowmeters measure flow based on Faraday's Law of Electromagnetic Induction. These flowmeters feature minimal pressure loss and a wide measurable flow range, with the ratio of maximum to minimum flow rate generally reaching 20:1 or higher. They are suitable for a broad range of industrial pipe diameters, provide an output signal linearly proportional to the measured flow, and ensure high measurement accuracy. Liquids with an electrical conductivity of ≥5 μS/cm are measurable by this device.

The clamp-type mounting design of electromagnetic flowmeters allows for easy installation and cleaning, making it a preferred choice for food production, pharmaceutical agent metering, and purified water monitoring applications.


WORKING PRINCIPLE

Based on Faraday's Law of Electromagnetic Induction, a pair of detection electrodes is mounted on the tube wall perpendicular to both the axis of the measuring tube and the magnetic lines of force. When the conductive liquid flows along the axis of the measuring tube, it cuts the magnetic lines of force to generate an induced electromotive force (EMF), which is detected by the two electrodes. The magnitude of this induced EMF is directly proportional to the flow rate, and is expressed by the formula:

E=KBVD
Where:E – Induced electromotive force;K – Coefficient related to magnetic field distribution and axial length;B – Magnetic induction intensity;V – Average flow velocity of the conductive liquid;D – Electrode spacing (inner diameter of the measuring tube).

The sensor transmits the induced electromotive force E as a flow signal to the converter. After a series of processes including amplification, conversion, filtering and digital processing, the converter displays the instantaneous flow rate and cumulative flow rate on a backlit dot-matrix liquid crystal display (LCD). The converter is equipped with a 4~20mA current output, pulse output and frequency output, as well as communication interfaces such as RS-485, and supports HART and MODBUS protocols.


PRODUCT ADVANTAGES

  • A new type of sanitary lining material is adopted to prevent the accumulation of measured medium residues in the measuring tube.

  • The measuring tube is free of obstructive moving parts and pressure loss, with low requirements for straight pipe sections.

  • The sensor adopts an upgraded generation of dedicated lining technology and is fitted with a special mirror-polished PFA lining.

  • The intelligent converter can display multiple measurement data simultaneously, including volume flow percentage, instantaneous flow rate and cumulative flow rate.

  • A quick-connection solution is employed, making the electromagnetic flowmeter easy to disassemble, maintain and clean. The intelligent converter is equipped with an LCD backlit display, enabling clear reading even in strong light or at night.


TECHNICAL PARAMETERS

Performance
Technical Parameters
Nominal Diameter
DN10mm ~ DN200mm
Accuracy
±0.5% of indicated value, optional ±0.3% or ±0.2% of indicated value
Lining Material
Food-grade hard rubber, F46, PFA
Electrode Material
SUS316, Hastelloy B/C
Electrode Type
Standard type
Connection Mode
Clamped connection
Medium Temperature
Integral type: -10℃ ~ +60℃; Split type: -10℃ ~ +160℃
Nominal Pressure
0.6 - 1.6 Mpa
Ambient Temperature
-25℃ ~ +60℃
Ambient Humidity
5 ~ 100% RH (Relative Humidity)
Medium Conductivity
≥20 μS/cm
Measuring Range
1500:1, Flow velocity setting <15 m/s
Structural Form
Integral type, Split type
Protection Grade
IP65, IP68 optional
Explosion-proof Mark
ExmdIIT 4
Product Standard
JB/T9248-2015 Electromagnetic Flowmeters



APPLICATION FIELD

Note: Electromagnetic flowmeters are applied in the following industries:
Petroleum, Chemical Industry, Iron and Steel, Food, Electric Power, Papermaking, Metallurgy, Water Supply and Drainage, Petrochemical, Medical and other industries.











TECHNICAL PARAMETERS

Performance

 

Technical Parameters

 

Nominal Diameter  

DN3 — DN3000mm

Accuracy

±0.5% of indicated value; optional ±0.3% or ±0.2% of indicated value

Lining Material

Polytetrafluoroethylene (PTFE), PFA, F46, Neoprene Rubber, Polyurethane Rubber, High-Temperature Rubber

Electrode Material

SUS316, Hastelloy B/C, Titanium (Ti), Tantalum (Ta), Platinum-Iridium Alloy, Stainless Steel Coated with Tungsten Carbide

Electrode Type

Standard Type, Scraper Type, Replaceable Type

Connection Method

Flange Connection, Insertion Connection, Clamp Connection, Sandwich Connection, Union Connection

Medium Temperature

Integral Type: -20℃ ~ +60

Split Type - Neoprene Rubber Lining, Polyurethane Lining: -20℃ ~ +60

-20℃ ~ +120, -20℃ ~ +180: -10℃ ~ +160

Nominal Pressure

0.6 ~ 4.0Mpa (Special pressure can be customized)

Ambient Temperature

-25℃ ~ +60

Ambient Humidity

~ 100% RH (Relative Humidity)

Medium Conductivity

20μs/cm

Measurement Range

1500:1, Flow velocity setting <15m/s

Structure Type

Integral Type, Split Type, Immersion Type, Explosion-Proof Type

Protection Level

IP65, IP68 optional

Explosion-Proof Mark

ExmdIIT4

Product Standard

JB/T9248-2015 Electromagnetic Flowmeters


FOLLOW US

Copyright @ Kaifeng Jingbo Automation Instrument Co., Ltd. . All rightsreserved lamps

International Sales

Email: zhangjianwei@kfjingbo.com

Phone/ WeChat: +86-18837860106

WhatsApp: +86-15637867223

WhatsApp: +86-13639690877

Service Area : Welcome global customers to

consult and cooperate, we support OEM/ODM services.


×
seo seo